Boiler Efficiency - Small Gains Can Bring Big Savings

industrial boiler room with equipment and boiler
Every boiler and steam system has a unique
set of efficiency challenges
There are numerous, actually about a half million, articles on the web about boiler efficiency. Because of the scale of even modest sized boilers, small increases in production efficiency can translate into very substantial monetary savings. Even when you have squeezed that final increment of efficiency from your boiler, a closer look will likely show there is something more you can do.
Increasing boiler and steam system efficiency is not a "one and done" proposition.
Boosting efficiency will undoubtedly involve controlling elements that were not controlled before, or at least controlling them in a more rigorous manner. This means additional instrumentation and controls that were not part of the system previously. Keeping those measurement and control elements in top working order is key to maintaining operating efficiency at stellar levels. The takeaway point here is that...
Higher efficiency operation is likely accompanied by increased system complexity.
Higher efficiency results from operating within a narrower set of conditions. Excess air, combustion temperature, flue gas composition, and more must be continuously monitored and maintained within the necessary envelope to keep the goal efficiency level throughout the varying demand levels on the system. With proper implementation, this additional complexity should not be an undue burden on the system operators. Automation and functionality built into modern measurement and control elements are capable of handling the normal operation and providing notice when conditions adversely vary from predicted or required ranges.
Increased maintenance activity is an integral part of reaping efficiency savings.
Steam systems, whether for heating a commercial building or driving an industrial process, generally involve extensive piping. The consumptive devices serviced by the system, most often where steam becomes condensate, are also part of the efficiency plan. Their productive use of the process steam contributes to overall savings. If an equipment unit, through the efforts of good maintenance and control, can perform its task with 95% of it previous consumption, that is a positive return on the effort and cost expended to boost performance.
Attaining elevated efficiency can result from added equipment, but maintaining high efficiency is a function of attitude and commitment. 
It is important that the managers, supervisors, technicians and contractors responsible for the day to day operation of the system consider efficient operation as a valuable and useful goal. Diligence, discipline, and attention to detail are solid elements of a successful maintenance program.

The US Department of Energy summarizes combustion efficiency on their website.
http://energy.gov/sites/prod/files/2014/05/f16/steam4_boiler_efficiency.pdf

Combustion Efficiency

Operating your boiler with an optimum amount of excess air will minimize heat
loss up the stack and improve combustion efficiency. Combustion efficiency
is a measure of how effectively the heat content of a fuel is transferred into
usable heat. The stack temperature and flue gas oxygen (or carbon dioxide)
concentrations are primary indicators of combustion efficiency.
Given complete mixing, a precise or stoichiometric amount of air is required
to completely react with a given quantity of fuel. In practice, combustion
conditions are never ideal, and additional or “excess” air must be supplied to
completely burn the fuel.
The correct amount of excess air is determined from analyzing flue gas oxygen
or carbon dioxide concentrations. Inadequate excess air results in unburned
combustibles (fuel, soot, smoke, and carbon monoxide), while too much results
in heat lost due to the increased flue gas flow—thus lowering the overall boiler
fuel-to-steam efficiency. The table relates stack readings to boiler performance.

Combustion Efficiency For Natural Gas















Here are some items that can impact boiler efficiency and steam system operating costs. While the list may point you toward some areas that need attention in your system, a good strategy is to consult a combustion specialist and share your concerns and goals for system operation. Their expertise will be an integral part of your good decision making.


  • Minimize losses due to leaks throughout the entire connected system.
  • Rigorously follow boiler and component manufacturer maintenance schedule recommendations.
  • Establish means to provide boiler blow-down when excess accumulation of dissolved solids occurs. Conductivity monitoring can be an effective indicator of dissolved solids.
  • Insulate all steam and condensate piping and traps. 
  • Establish steam system operation at the lowest effective pressure. Special condensate return accommodations may enhance ability to operate at lower pressure.
  • Perform timely maintenance of steam traps in accordance with best practices.
  • Use energy recovery units to heat makeup water with waste heat from flue gas.
  • Add variable speed drive controls to boiler feed pumps for lower energy consumption and finer control of feed flow.
  • Monitor flue gas O2  and temperature levels to determine combustion efficiency and optimize air-fuel ratio.
  • Monitor and control air flow and fuel flow using mass flow measuring and control devices for best accuracy.
  • On systems with multiple boilers, incorporate load sensing controls that will sequence and optimize the operation of the units in response to demand.
Certainly there is more detail involved in each item listed, plus numerous other potentially energy saving activities. By continuing to properly maintain your existing system and stay informed about new equipment and technology with promising application, you will keep your steam system operating at the top end of its efficiency range.

Boiler Combustion Efficiency System Pays Dividends

Industrial Boiler
Industrial Boiler
Steam and hot water use is prevalent throughout industrial processes. Production of these two media is most commonly accomplished with a boiler, many of which are heated by combustion of fossil fuel. Fuel fired boilers of a certain size become the focus of regulatory requirements for emissions. All boilers consume what would be construed by their owners as large amounts of costly fuel. Because of their high pressure and temperature, and the presence of a controlled combustion within an occupied facility, safety is a paramount concern.

There, fortunately, is a single solution that can help to attain useful goals with the three concerns of safety, fuel cost, and regulatory compliance. Applying an efficiency controller to manage the fuel to air ratio of the combustion system will deliver benefits far in excess of the cost to incorporate the necessary devices. The three basic goals for the fuel air controller are:
  • Maximize fuel efficiency
  • Minimize regulated emissions
  • Maintain safe operating condition
A good portion of all three goals can be accomplished through careful concerted parallel control of combustion air supply and fuel supply. The fuel air ratio must be subject to continual adjustment in response to current air conditions (which can vary on a daily basis) and the level of O2 in the flue gas. Controlling the air fuel ratio supports the following goals:
  • Preventing excess fuel vapors from entering the flue and creating an unsafe condition
  • Providing the correct amount of air to effectively combust the fuel supplied to the burner
  • Preventing excess air flow from reducing net heat transfer to the feedwater
  • Maintaining regulated emissions within required limits
  • Limiting fuel consumption to the minimum necessary to meet demand
Fireye® is a leading manufacturer of flame safeguard controls and burner management systems for commercial and industrial applications throughout the world. Their products, the first of which was developed in the 1930's, enhance the safety and efficiency of all fuel fired burners.

There are numerous capabilities built in to the company's PPC4000 series of fuel air ratio controllers. Some of the more notable include:
  • Precise fuel air ratio attained using parallel control of servos to regulate fuel and air supplies.
  • User selected burner profiles
  • Alarm contacts
  • PID operation
  • An array of inputs and outputs to accommodate sensors and devices needed to monitor and control boiler operation
  • Compatible with other products that provide additional flame and burner monitoring safety
  • Multiple boiler sequencing and cold start thermal shock protection
  • On board boiler efficiency calculation
  • User interface, optional larger touchscreen interface
Glance through just the first two pages of the document below to get a full description of the capability of this compact and comprehensive controller. You can get more detailed information, or get a professional evaluation of your current system efficiency, by contacting the combustion experts at CTi Controltech.