Crucial aspects of process control include the ability to accurately determine qualities and quantities of materials. In terms of appraising and working with fluids (such as liquids, steam, and gases) the flowmeter is a staple tool, with the simple goal of expressing the delivery of a subject fluid in a quantified manner. Measurement of media flow velocity can be used, along with other conditions, to determine volumetric or mass flow. The magnetic flowmeter, also called a magmeter, is one of several technologies used to measure fluid flow.

In general, magnetic flowmeters are sturdy, reliable devices able to withstand hazardous environments while returning precise measurements to operators of a wide variety of processes. The magnetic flowmeter has no moving parts. The operational principle of the device is powered by Faraday's Law, a fundamental scientific understanding which states that a voltage will be induced across any conductor moving at a right angle through a magnetic field, with the voltage being proportional to the velocity of the conductor. The principle allows for an inherently hard-to-measure quality of a substance to be expressed via the magmeter. In a magmeter application, the meter produces the magnetic field referred to in Faraday's Law. The conductor is the fluid. The actual measurement of a magnetic flowmeter is the induced voltage corresponding to fluid velocity. This can be used to determine volumetric flow and mass flow when combined with other measurements.

The magnetic flowmeter technology is not impacted by temperature, pressure, or density of the subject fluid. It is however, necessary to fill the entire cross section of the pipe in order to derive useful volumetric flow measurements. Faraday's Law relies on conductivity, so the fluid being measured has to be electrically conductive. Many hydrocarbons are not sufficiently conductive for a flow measurement using this method, nor are gases.

Magmeters apply Faraday's law by using two charged magnetic coils; fluid passes through the magnetic field produced by the coils. A precise measurement of the voltage generated in the fluid will be proportional to fluid velocity. The relationship between voltage and flow is theoretically a linear expression, yet some outside factors may present barriers and complications in the interaction of the instrument with the subject fluid. These complications include a higher amount of voltage in the liquid being processed, and coupling issues between the signal circuit, power source, and/or connective leads of both an inductive and capacitive nature.

In addition to salient factors such as price, accuracy, ease of use, and the size-scale of the flowmeter in relation to the fluid system, there are multiple reasons why magmeters are the unit of choice for certain applications. They are resistant to corrosion, and can provide accurate measurement of dirty fluids ' making them suitable for wastewater measurement. As mentioned, there are no moving parts in a magmeter, keeping maintenance to a minimum. Power requirements are also low. Instruments are available in a wide range of configurations, sizes, and construction materials to accommodate various process installation requirements.

As with all process measurement instruments, proper selection, configuration, and installation are the real keys to a successful project. Share your flow measurement challenges of all types with a process measurement specialist, combining your process knowledge with their product application expertise to develop an effective solution.

Flowmeter Basic Considerations

Multivariable flowmeter transmitter mass flowmeter flow temperature pressure
This multivariable vortex flowmeter provides output
of temperature, pressure and flow.
Image courtesy Azbil N.A.
Flow measurement, the quantifying of a point passage rate for gasses and liquids, is used throughout process applications in power generation, chemical manufacturing, petrochemicals, pulp and paper, water and wastewater, bio-science, semiconductor and many other manufacturing processes. There are two measurements of fluid flow in use: volumetric and weight or mass.

Flowmeters are used to measure the rate or quantity of fluid flow in an open or closed system. They are frequently found installed on piping systems, though there are also instruments capable of measuring liquid flow in open channels. The various measurement technologies have differing installation criteria, with some requiring placement of a sensing element in the flow path, others merely in contact with the flow medium, and still others with no media contact needed at all.

Flow measuring devices can be categorized in a few ways:
  • Inferential Types: Such as variable area flowmeters (rotameters), target flow meters and turbine flow meters.
  • Electrical Flow Meters: Such as electromagnetic flow meters, ultrasonic flowmeters and laser doppler anemometers.
  • Mechanical Type: Such as orifice plates, venturi tubes, flow nozzles, pitot tubes, positive displacement meters and mass flow meters.
  • Other: Such as vortex shedding flow meters, Coriolis, cross-correlation flowmeters, purge flow regulators, flow meters for solids flow measurement and flow switches.
Flow measurement instruments can be integrated into existing fluid transfer systems or installed on new lines, either inline or via insertion. Inline flowmeters mount in the piping system using downstream and upstream connections. Immersion flowmeters use a probe or sensor penetrating the piping, positioning the sensor in the flow stream.

For best results, it is important to heed manufacturer recommendations for installation. There are various flow characteristics that may have an adverse impact on measurement accuracy. Providing flow conditioning structures or maintaining minimum required straight runs on the upstream and downstream piping may be a requirement for some instruments. Each measurement technology will have installation recommendations and limitations.

For proper selection criteria, you should always know the physical state of the process media (solid, liquid, gas, steam), the condition of the media (clean, dirty, viscous, corrosive, flammable), piping size and range of flow rate. The process pressure and temperature can have an impact, as well.

Share your flow measurement challenges with a process measurement specialist and leverage your own knowledge and experience with their product application expertise to develop an effective solution.


Liquid Flow Measurement - Magnetic Flow Meters

electro magnetic flow meter flow measurement
Magnetic Flow Meter Assembly
Azbil
There are many technologies available for measuring liquid flow in industrial fluid processes. Each method has its own set off attributes that will make it an advantageous selection for some applications. A familiarity with those attributes can help you make an effective selection.

Magnetic flow meters, also called electromagnetic flow meters or "magmeters", operate on a very simple principal. An electrically conductive liquid moving through a magnetic field will generate a voltage that is related to the velocity of the liquid. Magnetic flow meters have no moving parts and present little to no pressure drop to the piping system into which they are installed. It is a flow-through device and does require the cross section of the pipe to be completely filled by the subject fluid in order to produce a useful reading.

Some characteristics of magnetic flow meters.

  • Sensor assembly has no moving parts.
  • The subject fluid must be electrically conductive.
  • Measurement reflects fluid velocity and is not impacted by viscosity, density, or static pressure.
  • Other than regular calibration and operational checkout, no maintenance requirements.
  • Produces velocity reading only. Need other inputs to produce a mass flow value.
  • Bidirectional flow measurement is possible.
  • Little or no pressure drop associated with the instrument.
  • Comparatively higher in weight.
  • Accurate measurements require entire pipe cross section to be full of fluid.
There is more to know. A data sheet is included below that details the Azbil Smart Two-wire Magnetic Flowmeter. For even more information, reach out to a process measurement specialist and share your flow measurement challenges. Combining your process knowledge with their product application expertise will lead to the most effective solutions.